A Low-Cost Instrument to Monitor Sulphur Dioxide Emissions Based on The DOAS Method

Authors

  • Nur Zen BBTPPI
  • Haryono Setiyo Huboyo Department of Environmental Engineering, Diponegoro University
  • Moch. Syarif Romadhon BRIN
  • Januar Arif Fatkhurrahman Center for Industrial Pollution Prevention Technology and Standardization
  • Sidna Kosim Amrulah Center of Industrial Pollution Prevention Technology, Indonesia

DOI:

https://doi.org/10.21771/jrtppi.2023.v14.no1.p1-7

Keywords:

DOAS, Emission, Sulphur dioxide

Abstract

Various techniques to measure SO2 concentration based on Differential Optical Absorption Spectroscopy (DOAS) have been widely developed and applied for various measurements. However, most of the applications are still relatively expensive. Some efforts have been made to reduce the cost by using Ultraviolet Light Emitting Diodes (LEDs) as light sources, showing promising results. Further reductions can be possibly made by providing an alternative to replace high spectral resolution spectrometers widely used in DOAS applications since those spectrometers are commercially expensive. This paper studies the feasibility of a DOAS instrument using a low-cost spectrometer and UV-LEDs as light sources. The resolution of the spectrometer is 0.7 nm. With this resolution, it is expected that the instrument hardly captures narrow band structures of SO2 optical absorption in the spectral range between 280 nm and 320 nm when measuring SO2 gas concentration lower than the limits of SO2 emissions regulated by the Indonesian government. To compensate for this drawback, narrow and broad bands of optical absorption structures are considered in the data analysis to achieve a detection limit far below the regulated limits. To capture the broadband structures, four UV-LEDs are used to cover spectral absorption from 250 nm to 320 nm. The instrument was calibrated using eight different standard concentrations of SO2. The correlation between the readings and the standard concentrations is high, indicated by the Pearson correlation coefficient of 0.9999. It was also found that the lowest concentration the instrument can distinguish from blank samples or the Limit of Detection is 16 ppm. However, the instrument can precisely measure concentrations higher than or equal to 25 ppm with a standard deviation of less than 10% of the mean concentration measured from five measurements. This is far below the required legal limits, below 229 ppm. After the calibration, the DOAS instrument was used to measure SO2 sampled from the emission of burning coals. To compare, a commercial SO2 sensor was used to measure the same gas. The results indicate that the difference in the readings between the two instruments is around 6% of the concentration.

References

Akimoto, H., & Narita, H. (1994). Distribution of SO2, NOx and CO2 emissions from fuel combustion and industrial activities in Asia with 1° × 1° resolution. Atmospheric Environment, 28(2), 213–225. https://doi.org/10.1016/1352-2310(94)90096-5

Armbruster, D. A., & Pry, T. (2008). Limit of blank, limit of detection and limit of quantitation. The Clinical Biochemist Reviews, 29 (Suppl 1), S49.

Badan Standardisasi Nasional Indonesia. (2005). Emisi Gas Buang – Sumber Tidak Bergerak – Bagian 3: Oksida-Oksida Sulfur (SOx) - Seksi 1 : Cara Uji Dengan Metoda Turbidimetri Menggunakan Spektofotometer.

Badan Standardisasi Nasional Indonesia. (2009). Emisi Gas Buang – Sumber Tidak Bergerak – Bagian 18 : Cara Uji Sulfur Dioksida (SO2) Secara Turbidimetri Menggunakan Spektrofotometer.

Bani, P., Oppenheimer, C., Tsanev, V., Scaillet, B., Primulyana, S., Saing, U. B., Marlia, M. (2022). Modest volcanic SO2 emissions from the Indonesian archipelago. Nature Communications 2022 13:1, 13(1), 1–15. https://doi.org/10.1038/s41467-022-31043-7

EPA CTM-022. (1995). EPA CTM-022.

Fatkhurrahman, J. A., Rasti, I., Sari, J., Andriani, Y., Romadhon, M. S., Zen, N., & Prasetio, A. (2020). Jurnal Riset Teknologi Pencegahan Pencemaran Industri DOAS Calibration Technique for SO2 Emission Measurement Based on H2SO4 and Na2SO3 Reaction, 11(1), 36–45.

Hermans, C., Vandaele, A. C., & Fally, S. (2009). Fourier transform measurements of SO2 absorption cross sections:: I. Temperature dependence in the 24 000–29 000 cm− 1 (345–420 nm) region. Journal of Quantitative Spectroscopy and Radiative Transfer, 110(9–10), 756–765.

HITRANonline - Absorption Cross Section Search. (2022).

Kampa, M., & Castanas, E. (2008). Human health effects of air pollution. Environmental Pollution, 151(2), 362–367.

Laaksonen, A., Kulmala, M., Berndt, T., Stratmann, F., Mikkonen, S., Ruuskanen, A., Viisanen, Y. (2008). Atmospheric Chemistry and Physics SO2 oxidation products other than H2SO4 as a trigger of new particle formation. Part 2: Comparison of ambient and laboratory measurements, and atmospheric implications. Atmos. Chem. Phys, 8, 7255–7264.

MenLHK RI. (2019). Peraturan MenLHK RI No. 15 Tahun 2019 Tentang Baku Mutu Emisi Mesin Dengan Pembakaran Dalam.

Rodhe, H. (1999). Human impact on the atmospheric sulfur balance, 51–110. https://doi.org/10.3402/tellusa.v51i1.12309

Stutz, J., & Platt, U. (1996). Numerical analysis and estimation of the statistical error of differential optical absorption spectroscopy measurements with least-squares methods. Applied Optics, 35(30), 6041–6053.

Yunita, R. D., & Kiswandono, A. A. (2017). Kajian Indeks Standar Pencemar Udara (ISPU) Sulfur Dioksida (SO2) Sebagai Polutan Udara Pada Tiga Lokasi Di Kota Bandar Lampung. Analit: Analytical and Environmental Chemistry, 2(1).

Downloads

Published

2023-05-02

How to Cite

Zen, N., Huboyo, H. S., Romadhon, M. S., Fatkhurrahman, J. A., & Amrulah, S. K. (2023). A Low-Cost Instrument to Monitor Sulphur Dioxide Emissions Based on The DOAS Method. Jurnal Riset Teknologi Pencegahan Pencemaran Industri, 14(1), 1–7. https://doi.org/10.21771/jrtppi.2023.v14.no1.p1-7

Issue

Section

Articles

Most read articles by the same author(s)

<< < 1 2